In Med

PDF update in progress...

Radiation_Therapy_Phantoms 

Dynamic Thorax Phantom

Dynamic_Thorax_Phantom

True 3D motion in a solid epoxy phantom.

The Dynamic Thorax Phantom is a precision instrument for investigating and minimizing the impact of tumor motion inside the lung. It provides known, accurate and repeatable three-dimensional target motion inside a tissue equivalent phantom. It is designed for comprehensive analysis of image acquisition, planning and dose delivery in image-guided radiation therapy.

Dynamic Platform

Dynamic_Platform

Programmable motion for any platform.

The Dynamic Platform provides an economical, user-friendly solution for the complex tasks associated with tumor motion and patient positioning in radiation therapy. The device enables precisely controlled inferior-superior motion, up to 50 mm for any phantom up to approx 32kg. A removable pin system in the main platform allows consistent placement and fixation of almost any phantom and traditional laser alignment marks enable accurate positioning of the entire device.

Dosimetry Verification Phantom

dosimetry_verification_phantoms

Standard ATOM® phantoms are now manufactured by CIRS and include bone, lung and soft tissue compositions formulated for accurate simulation for diagnostic and therapy energies. Photon attenuation values between 30 keV and 20 MeV are within 1% for bone and soft tissue substitutes and within 3% for lung substitute. The skeleton included with these phantoms is made from an average composition of normal cortical and trabecular bone and includes vertebral disks and spinal cord.

Standard phantom includes head, torso, upper femur and genitalia. Legs and arms are included with the newborn and 1 year pediatric phantoms. Legs and arms can be manufactured for other phantoms upon special request.

Radiosurgery Head Phantom

radiosurgery_Head_Phantom

The CIRS Radiosurgery Head Phantom was designed to improve the accuracy of treatment plan verification in radiosurgery. It allows for 3D dose verification in a large cranial volume.

Virtually Human Male Pelvis Phantom - 801-P-F

male_pelvis_phantom

The CIRS Model 801-P-F phantom is the most realistic, tissue equivalent phantom available. The phantom was designed for use in diagnostic radiology and radiation therapy for imaging dosimetry teaching and demonstration applications. The phantom is made from proprietary epoxy materials that mimic the density and radiation attenuation properties of human tissue within 1% from 50 keV to 25 MeV. It contains anatomically precise bone, cartilage, spinal cord, vertebral disks, muscle, intestines, bladder, prostate, rectum and interstitial fat.

Dental and Diagnostic Head Phantom - 711-HN

Dental__Diagnostic_Head

Our most realistic maxillofacial phantom for dental cone beam CT & panoramic x-ray.

The 711-HN Dental and Diagnostic Head Phantom is a standard of reference for diagnostic radiology of the head. The phantom is designed to assist technical and clinical staff in the selection, monitoring, training and verification of scanning parameters common to most radiological procedures requiring fine anatomical details. The 711-HN is ideal for determining optimum system settings, commissioning new equipment, monitoring system performance and training in dental X-ray, panoramic X-ray, CT and cone beam CT procedures.

IMRT Homogeneous Phantom - 002H5

IMRT_Homogeneous_Phantom

Complete QA from CT imaging to dose verification.

The 002H5 IMRT Phantom for Film and Ion chamber dosimetry is designed to address the complex issues surrounding the commission and comparison of treatment planning systems, while providing a simple yet reliable method for verification of individual patient plans and delivery. The 002H5 is homogeneous and elliptical in shape. It properly represents human anatomy in size and proportion.

IMRT Thorax Phantom - 002LFC

IMRT_Thorax_Phantom

Complete QA from CT imaging to dose verification.

The 002LFC IMRT Thorax Phantom for Film and Ion chamber Dosimetry is designed to address the complex issues surrounding the commission and comparison of treatment planning systems while providing a simple yet reliable method for verification of individual patient plans and delivery. The 002LFC is elliptical in shape and properly represents an average human torso in proportion, density and two-dimensional structure.

IMRT Pelvic 3D Phantom - 002PRA

IMRT_Pelvic_3d_phantom

Complete QA from CT imaging to dose verification.

The 002PRA IMRT phantom is designed to address the complex issues surrounding the commission and comparison of treatment planning systems and verification of individual patient plans and delivery. The 002PRA properly represents human pelvic anatomy in shape, proportion and structure as well as density. This enables the thorough analysis of both the imaging and dosimetry systems. The phantom is elliptical in shape, approximates the size of an average patient, and has a tissue equivalent, three dimensional skeleton. The phantom also supports film dosimetry with not only standard radiographic films but also GafChromic® media. Optional inserts are available to support a variety of other detectors including TLD’s, MOSFET, and diodes.

IMRT Head and Neck Phantom - 002HN

IMRT_Head_and_Neck_Phantom

Complete QA from CT imaging to dose verification.

The 002HN IMRT phantom is designed to address the complex issues surrounding commissioning and comparison of treatment planning systems and verification of individual patient plans and delivery. The 002HN properly represents human head and neck anatomy in shape, proportion and structure as well as density. Tissue equivalent interchangeable rod inserts for ionization chambers allow for point dose measurements in multiple planes in the phantom and film calibration.

An optional cranial bone ring is also available.

IMRT Head & Torso Freepoint Phantom - 002H9K

IMRT_Head__Torso_Freepoint_Phantom

Complete QA from CT imaging to dose verification.

The Model 002H9K allows the user to choose any point dose location within a circular area with a diameter of 11.2 cm by simply adjusting the two rotating cylinders. Lung and bone equivalent rods can be positioned at any location within the circular area for assessment of heterogeneity correction. Remove the center cylinder from the phantom body to simulate head and neck set-ups.

Cube Phantom - 009

cube_phantom

The most convenient device for routine QA and IMRT applications.

The 009 Cube 20 Phantom was designed for routine QA in RT and IMRT applications where ease of use and quick set-up are important. The Cube 20 is manufactured from Plastic Water® DT which faithfully mimics water within 1% from 50 keV to 25 MeV. This enables complete QA from CT image acquisitions to therapy dose verifications. The 20cm cubic dimension was chosen as a suitable approximation for both head/neck and torso treatments. All the edges are rounded to avoid CT artifacts.

Water Equivalent Mini Phantom - 670

Water_Equivalent_Mini_Phantom

Permits precise evaluation of scatter.

The Water Equivalent Mini Phantom for Radiotherapy eliminates scatter radiation and X-Ray beam electron contamination during the ion chamber measurements at a reference depth of 10cm. The Model 670 provides an excellent tissue simulation and opportunity of true dose comparison with the 30 x 30cm Plastic Water® slab phantom.

CBCT Electron Density Phantom - 062A

CBCT_Electron_Density_Phantom

Increase confidence in HU values for use in Adaptive Radiation Therapy.

The Cone beam (CBCT) Electron Density Phantom is an extended version of the CIRS Model 062A Electron Density Phantom and specifically designed for Cone Beam CT Imaging systems.

Electron Density Phantom - 062

Electron_Density_Phantom

Increase confidence in HU values for use in Adaptive Radiation Therapy.

The Cone beam (CBCT) Electron Density Phantom is an extended version of the CIRS Model 062A Electron Density Phantom and specifically designed for Cone Beam CT Imaging systems.

Plastic Water®

Plastic_Water

Calibrate photon and electron beams within 0.5% of true water dose.

Unlike other water equivalent plastics on the market, Plastic Water® is flexible and will not break under impact. Plastic Water® is the only calibration material available in 1 mm thicknesses and is the only material which agrees with true water within 0.5% above 7 MeV.

NEMA PET Scatter Phantom - 800

NEMA_PET_Scatter_Phantom

Designed specifically for NEMA Standard NU2-2001.

The 800 PET Scatter Phantom is a solid right circular polyethylene cylinder, designed to test scatter fraction, count losses and random measurements in accordance with NEMANU2- 2001.