Sources for Dedicated PET

|
Isotope Products Laboratories is the leader in source manufacturing for Positron Emission Tomography (PET) studies. IPL manufactures Ge-68 Transmission Sources and quality assurance sources for major dedicated PET camera makers such as GE Medical Systems, Siemens Medical Systems, Positron Corporation and others. In addition, IPL manufactures Cs-137 and Na-22 sources for dedicated PET cameras for Philips Medical Systems and Siemens/CTIMI Medical Systems.
Custom Sources: IPL can manufacture PET sources for custom needs. Please contact an IPL Medical Imaging Customer Service Representative for additional information.
|
|
|
Siemens Medical Systems ECAT EXACT/HR/ART/951R/951/31/08™
|
Phantom for quality assurance.
Specifications:
-
IPL Drawing Number: A1911
-
Encapsulation: High density polyethylene right circular cylinder
-
Dimensions: 21.3 (Dia) x 22.5cm (H)
-
Active Volume: 6L
-
Source Matrix: Epoxy
-
Density: 1.0 g/cm3 ±7%
-
Nuclide Purity: >99%
-
Uniformity: ±5% coefficient of variation measured with a resolution of 1 cm3 source volume
-
Calibration: Calibrated and NIST traceable with an absolute activity accuracy ±5% of measured value.
|
|
| GE-68 Line

| The Ge-68 line source is utilised to calibrate Positron Emission Tomography scanner systems. It is used as a transmission standard or a source of annihilation photons to provide a tissue density correction to permit more accurate diagnostic scanning of patients. The source is mounted on a movable holder which revolves around the patient’s head or body. The source emits photons which attenuate in the patient to varying degrees, depending on the particular location of the source with respect to the patient. The counter-opposed detectors on the PET system detect the radiation at any given point and the system software computes and stores this information. The instrumentation “corrects” the annihilation radiation intensity emitted from the administered radiopharmaceutical, automatically adjusting for the effect of the density and thickness of the tissue through which the photons travel at all the reference locations. This provides a “background corrected” scan of the patient to optimize resolution and define more precisely the distribution of the radiopharmaceutical. |
|
GE Medical Systems PET Advance™
|
Transmission and Quality Assurance Pin
Specifications:
-
IPL Drawing Number: A3407
-
Encapsulation: Triply encapsulated 304 stainless steel
-
Overall Length: 225.6mm
-
Active Length: 155mm
-
Overall Diameter: 3.96mm (handle is 19.05mm)
-
Active Diameter: 1.52mm
-
Nuclide Purity >99%
-
Uniformity ≤5% integral non-uniformity measured in centimeter long segments.
|
|
GE Medical Systems Discovery ST™
|
Normalisation Pin.
Specifications:
-
IPL Drawing Number: A3429
-
Encapsulation: 304 stainless steel
-
Overall Length: 291.3mm
-
Active Length: 160mm
-
Overall Diameter: 3.96mm (handle is 19mm)
-
Active Diameter: 1.40mm
-
Nuclide Purity >99%
-
Uniformity ≤5% integral non-uniformity measured in centimeter long segments.
|
|
|
Siemens Medical Systems ECAT EXACT/HR™
Transmission Pin Specifications:
-
IPL Drawing Number: A3418-2
-
Encapsulation: Singly encapsulated 304 stainless steel
-
Overall Length: 192mm
-
Active Length: 183mm
-
Overall Diameter: 3.18mm
-
Active Diameter: 2.36mm
-
Nuclide Purity: >99%
-
Uniformity: ≤5% integral non-uniformity measured in centimeter long segments.
Download the PET Source PDF
|
|
|