CT Simulator - 004

|
|
A simple and effective method for accurate and reliable bone mineral measurements, the 004 CT simulator is designed to be used immediately on any whole body CT scanner. The 004 accurately simulates the size, shape and CT density of human tissue and does not require any special setup or software configuration.
|
|
|
NEMA SCA&I - 901

|
|
The CIRS Model 901 NEMA SCA&I phantom has been designed to evaluate and standardise catheterisation image quality. The phantom specifically enables voluntary compliance with the recently published performance standard NEMA XR 21 and is ideal for routine assessment of the entire imaging system.
|
|
|
Radiography Fluoroscopy Accreditation Phantom - 903

|
|
The CIRS Model 903 Radiography / Fluoroscopy QA Phantom is designed to provide physicians with an opportunity for a comprehensive review of their Radiography/Fluoroscopy facility and image quality programs. The Radiography / Fluoroscopy QA Phantom can be used for initial QA assessment and routine monthly QA testing to help ensure patients are receiving the best possible x-ray examinations.
|
|
|
Spiral/Helical CT Phantom

|
|
Optimise collimation and table speed (pitch) to ensure detection of small lesions in the abdominal cavity.
The Spiral/Helical CT Phantom is designed to test scanning protocols to verify that small low contrast lesions will be detected. The phantom permits complete testing of low contrast lesion detection when scan parameters are varied. These parameters include collimation, pitch, reconstructed field of view, reconstruction algorithms, z-axis interpolators, kVp, mA and rotation time. Testing can be applied to protocols designed for head and abdomen.
|
|
|
CT Dose Phantom
|
|
The CIRS CT Dose Phantom is manufactured to comply with the Food and Drug Administration’s performance standard for diagnostic x-ray systems. Each phantom consists of two 14 cm thick solid PMMA disks measuring 16cm (head) and 32cm (body) in diameter. There are a total of 9 through holes with acrylic rods to plug the holes when not in use. Through holes are 1.31 cm in diameter to accommodate standard CT probes.
|
|
|
AAPM CT Performance Phantom - 610

|
| The 610 AAPM CT Performance Phantom offers the user a single test object that measures ten distinct CT performance parameters. The 610 is also capable of taking the following measurements; noise, size independence, sensitivity/detect-ability, radiation dose, mechanical alignment, spatial uniformity, beam hardening, HU linearity, slice thickness, spatial resolution and line spread function. |
|
|
Tissue Equivalent CT Dose Phantoms

|
|
The CIRS Tissue Equivalent CT Dose Phantoms are designed to more accurately simulate the patient’s anatomy. Dose Phantoms are available in a range of sizes, from small infants to large adult patients, rendering more accurate and reliable CT dose data. There are eight abdominal, eight thorax, and four head phantoms of different sizes/ages available.
|
|
|
3D Sectional Torso Phantom - 600

|
|
Includes 12 internal organ tissues.
The CIRS Model 600 Anthropomorphic Torso Phantom is designed to provide an accurate simulation of an average torso for medical imaging and dosimetry applications. The Model 600 also includes 12 internal organ structures, all of which match the tissue density of actual organs, and can be clearly visualised.
|
|
|
3D Anthropomorphic Torso Phantom

|
|
The CIRS Anthropomorphic Torso Phantom is designed to provide an accurate simulation of an average male torso for medical imaging applications. The removable organs enable flexibility in the placement of TLD’s, contrast agents, etc.
|
|
|
MicroMouse Phantom - 090

|
|
Provides standard of reference for Micro-CT scanners
The 090 MicroMouse Phantom, provides a tool for quantifying calcium and bone density with respect to x-ray attenuation and absorption properties.
The 090 can be used to evaluate Micro-CT scanners as you would standard whole body scanners. The targets are suitable for determining contrast detect-ability and estimating low-contrast resolution.
|
|
|
DEXA Phantom

|
|
The DEXA Phantom is a quality control tool for Dual-Energy X-ray Absorptiometry (DEXA) instruments, featuring an acrylic-embedded calcium hydroxyapatite (CHA) step-wedge. Advanced design features make it the best choice for assessing DEXA instrument stability. It can be successfully used on all mainstream DEXA instruments.
|
|
|
Dosimetry Verification Phantoms

|
|
Standard ATOM® phantoms are now manufactured by CIRS and include bone, lung and soft tissue compositions formulated for accurate simulation for diagnostic and therapy energies. Photon attenuation values between 30 keV and 20 MeV are within 1% for bone and soft tissue substitutes and within 3% for lung substitute. The skeleton included with these phantoms is made from an average composition of normal cortical and trabecular bone and includes vertebral disks and spinal cord.
Standard phantom includes head, torso, upper femur and genitalia. Legs and arms are included with the newborn and 1 year pediatric phantoms. Legs and arms can be manufactured for other phantoms upon special request.
|
|
|
Radiosurgery Head Phantom

|
|
The CIRS Radiosurgery Head Phantom was designed to improve the accuracy of treatment plan verification in radiosurgery. It allows for 3D dose verification in a large cranial volume.
|
|